FACILITY ASSET MANAGEMENT SERVICES
Picture
Picture
FCG's consulting and design staff includes experienced roofing specialists with over 135 years experience in the construction industry. We specialize in roofing design, consulting, inspection, estimating, CAD design, installation, and evaluation. All of our staff members have worked as construction observers and as roofers. Our CAD designers have over 20 years of experience.
  • Evaluation
  • Design
  • Construction Observation / Monitoring
  • Non Destructive Testing
  • Thermographic Services
  • Failure Analysis
  • Contract Administration
ROOF CONSULTING SERVICES
Picture
Picture
We provide experienced roofing technicians for the monitoring of roof materials, workmanship, and sequence of construction per project specifications, and manufacturer recommendations.  Special attention is given to material verification, moisture detection in component materials, and material application.  
  • Review historical records.
  • Perform a thorough visual inspection.
  • Obtain roof samples for laboratory examination.
  • Prepare a photographic record of discrepancies and potential problems.
  • Scrutinize roof drainage.
  • Prepare a report to include the results of the investigation, along with the conclusions, recommendations, and cost estimates.
THERMOGRAPHIC SERVICES
Picture
Picture
​FCG provides a wide range of thermographic services.   Our Thermographers are certified by the infraspection Institute. FCG uses infrared, capacitance and nuclear equipment to perform nondestructive testing.  The following is a review of the equipment and testing procedures:

Infrared Thermal Imaging Radiometer
The Radiometer is used to detect the presence of moisture in roof systems due to the differential heat loss between wet and dry insulation.
 
Nuclear Moisture Meter
The nuclear gage we use is a noninvasive moisture detector (AM241 Be).  The depth of accurate readings of the nuclear moisture detector is approximately 6 inches.

Capacitance Leak Seeker
The capacitance scanner detects the presence of moisture in the roof system due to the differences in the dielectric constant between water and roofing materials. Each of these systems has unique limitation and neither should be used in the presence of standing water; therefore utilizing two of them in combination provides a desirable cross check with a correspondingly higher confidence level in the results obtained.
Picture
Picture
Our Experience Encompasses:​
  • In-plant Electrical panels, switches, terminals, and motors.
  • In-plant Boilers, stacks, check valves, pumps, blowers, and steam lines.
  • ​Control Panels ,switches and terminals.
  • Tank Farm, heat traced lines, pumps and motors.
  • Production Equipment, motors, bearings, pumps, hot water lines, steam lines, and heat loss equipment.
  • Building Envelopes, doors, windows, ventilators, interior and exterior insulation systems.
  • Roofing: over 50 million square feet.
  • Electrical Power Substations